schneider-electric easergy_t300_firmware 对路径名的限制不恰当(路径遍历)

admin 2023-11-30 08:36:49 Ali_nvd 来源:ZONE.CI 全球网 0 阅读模式
schneider-electric easergy_t300_firmware 对路径名的限制不恰当(路径遍历)

CVE编号

CVE-2020-25176

利用情况

暂无

补丁情况

N/A

披露时间

2022-03-19
漏洞描述
Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead to remote code execution.
解决建议
建议您更新当前系统或软件至最新版,完成漏洞的修复。
参考链接
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-04
https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1131699
https://www.cisa.gov/uscert/ics/advisories/icsa-20-280-01
https://www.xylem.com/siteassets/about-xylem/cybersecurity/advisories/xylem-m...
受影响软件情况
# 类型 厂商 产品 版本 影响面
1
运行在以下环境
应用 rockwellautomation aadvance_controller * Up to (including) 1.40
运行在以下环境
应用 rockwellautomation isagraf_free_runtime * Up to (including) 6.6.8
运行在以下环境
应用 rockwellautomation isagraf_runtime * From (including) 5.0 Up to (excluding) 6.0
运行在以下环境
系统 rockwellautomation micro810_firmware - -
运行在以下环境
系统 rockwellautomation micro820_firmware - -
运行在以下环境
系统 rockwellautomation micro830_firmware - -
运行在以下环境
系统 rockwellautomation micro850_firmware - -
运行在以下环境
系统 rockwellautomation micro870_firmware - -
运行在以下环境
系统 schneider-electric easergy_c5_firmware * Up to (excluding) 1.1.0
运行在以下环境
系统 schneider-electric easergy_t300_firmware * Up to (including) 2.7.1
运行在以下环境
系统 schneider-electric epas_gtw_firmware 6.4 -
运行在以下环境
系统 schneider-electric micom_c264_firmware * Up to (excluding) d6.1
运行在以下环境
系统 schneider-electric pacis_gtw_firmware 5.1 -
运行在以下环境
系统 schneider-electric pacis_gtw_firmware 5.2 -
运行在以下环境
系统 schneider-electric pacis_gtw_firmware 6.1 -
运行在以下环境
系统 schneider-electric pacis_gtw_firmware 6.3 -
运行在以下环境
系统 schneider-electric saitel_dp_firmware * Up to (including) 11.06.21
运行在以下环境
系统 schneider-electric saitel_dr_firmware * Up to (including) 11.06.12
运行在以下环境
系统 schneider-electric scd2200_firmware * Up to (including) 10024
运行在以下环境
系统 xylem multismart_firmware * Up to (excluding) 3.2.0
运行在以下环境
硬件 rockwellautomation micro810 - -
运行在以下环境
硬件 rockwellautomation micro820 - -
运行在以下环境
硬件 rockwellautomation micro830 - -
运行在以下环境
硬件 rockwellautomation micro850 - -
运行在以下环境
硬件 rockwellautomation micro870 - -
运行在以下环境
硬件 schneider-electric cp-3 - -
运行在以下环境
硬件 schneider-electric easergy_c5 - -
运行在以下环境
硬件 schneider-electric easergy_t300 - -
运行在以下环境
硬件 schneider-electric epas_gtw - -
运行在以下环境
硬件 schneider-electric mc-31 - -
运行在以下环境
硬件 schneider-electric micom_c264 - -
运行在以下环境
硬件 schneider-electric pacis_gtw - -
运行在以下环境
硬件 schneider-electric saitel_dp - -
运行在以下环境
硬件 schneider-electric saitel_dr - -
CVSS3评分 9.8
  • 攻击路径 网络
  • 攻击复杂度 低
  • 权限要求 无
  • 影响范围 未更改
  • 用户交互 无
  • 可用性 高
  • 保密性 高
  • 完整性 高
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CWE-ID 漏洞类型
CWE-22 对路径名的限制不恰当(路径遍历)