bosch amc2_firmware 使用硬编码的凭证
CVE编号
CVE-2021-23842利用情况
暂无补丁情况
N/A披露时间
2022-01-20漏洞描述
Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\'s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet.解决建议
建议您更新当前系统或软件至最新版,完成漏洞的修复。
参考链接 |
|
---|---|
https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html |
受影响软件情况
# | 类型 | 厂商 | 产品 | 版本 | 影响面 | ||||
1 | |||||||||
---|---|---|---|---|---|---|---|---|---|
运行在以下环境 | |||||||||
应用 | bosch | access_management_system | 3.0 | - | |||||
运行在以下环境 | |||||||||
应用 | bosch | access_professional_edition | * | Up to (including) 3.8.0 | |||||
运行在以下环境 | |||||||||
应用 | bosch | building_integration_system | * | Up to (excluding) 4.9.1 | |||||
运行在以下环境 | |||||||||
系统 | bosch | amc2_firmware | - | - | |||||
运行在以下环境 | |||||||||
硬件 | bosch | amc2 | - | - |
- 攻击路径 本地
- 攻击复杂度 低
- 权限要求 低
- 影响范围 未更改
- 用户交互 无
- 可用性 无
- 保密性 高
- 完整性 高
CWE-ID | 漏洞类型 |
CWE-798 | 使用硬编码的凭证 |
Exp相关链接

版权声明
本站原创文章转载请注明文章出处及链接,谢谢合作!
评论