授权机制不恰当

admin 2023-11-30 03:47:28 Ali_nvd 来源:ZONE.CI 全球网 0 阅读模式
授权机制不恰当

CVE编号

CVE-2023-22610

利用情况

暂无

补丁情况

N/A

披露时间

2023-02-01
漏洞描述
A CWE-285: Improper Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure™ Geo SCADA Expert 2019, EcoStruxure™ Geo SCADA Expert 2020, EcoStruxure™ Geo SCADA Expert 2021 (All versions prior to October 2022), ClearSCADA (All Versions).
解决建议
建议您更新当前系统或软件至最新版,完成漏洞的修复。
参考链接
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02&p_en...
受影响软件情况
# 类型 厂商 产品 版本 影响面
1
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 - -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7268.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7322.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7429.2 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7457.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7488.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7522.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7545.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7578.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7613.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7641.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7690.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7714.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7742.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7777.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7808.2 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7840.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7875.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7896.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7936.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.7980.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.8015.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.8108.2 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.8122.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.8155.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.8172.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.8197.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.8220.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2019 81.8267.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 - -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.7551.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.7578.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.7613.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.7641.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.7692.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.7717.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.7742.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.7787.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.7809.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.7840.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.7875.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.7913.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.7936.2 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.7980.2 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.8017.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.8108.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.8122.2 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.8155.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.8181.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.8197.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.8221.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2020 83.8267.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2021 - -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2021 84.8027.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2021 84.8108.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2021 84.8120.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2021 84.8158.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2021 84.8182.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2021 84.8197.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2021 84.8218.1 -
运行在以下环境
应用 schneider-electric ecostruxure_geo_scada_expert_2021 84.8269.1 -
CVSS3评分 7.5
  • 攻击路径 网络
  • 攻击复杂度 低
  • 权限要求 无
  • 影响范围 未更改
  • 用户交互 无
  • 可用性 高
  • 保密性 无
  • 完整性 无
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CWE-ID 漏洞类型
CWE-285 授权机制不恰当
CWE-863 授权机制不正确
NVD-CWE-Other
- avd.aliyun.com
weinxin
版权声明
本站原创文章转载请注明文章出处及链接,谢谢合作!
N/A Ali_nvd

N/A

N/ACVE编号 CVE-2024-9120利用情况 暂无补丁情况 N/A披露时间 2024-09-23漏洞描述Use after free in Dawn
评论:0   参与:  0